When the heating/cooling load is of air condition type which can normally be produced by heat -pump devices, comparing with modern GTCC, they are not always energy -savable! Based on "total heat efficiency" of the thermodynamics first law for judging the energy-saving of distributed CCHP systems, there are always some false information, whereas "exergy efficiency" based.
采用基于热力学第一定律的总热效率来判断热电冷联产系统的节能性往往会造成假象,只有用基于热力学第二定律的(?)效率来判断才是科学的。
Heat-to-electric ratio and thermal efficiency of power plant are used as the energy-saving indexes for cogeneration in China.
我国以热电比、全厂总热效率界定热电联产节能指标。
16%, the total effective rate 87.
结果 :症状改善率达 85 5 9%~ 89 16 %,总有效率达 87 6 4%。
%,5 cases make progress,with a total effective rate was 43.
7%,5例取得进步,总有效率为43。
The effects of factors,including slurry viscosity,slurry density,intake highness,diameter of intake line and the velocity in intake line flow,on the coefficient and total efficiency of reciprocating slurry pump are studied through the orthogonal test.
应用正交试验研究了浆料的黏度、密度、泵排出压力、吸入条件(吸入管长度、吸入高度、介质在吸入管内流速)等因素对往复式料浆泵的实际流量及总效率的影响,得到了最优输送水平组合,并得出了流量系数和总效率的拟合公式。
The simulation results show that as the coverage ratio increases,the electrical yield and the total efficiency of photovoltaic-Trombe wall increases,but the indoor temperature and the thermal efficiency of photovoltaic-Trombe wall decreases.
模拟结果表明:随着覆盖率的增加,该墙体发电量和总效率增大,但热效率和室内温度降低;覆盖率对光电池发电效率影响很小,对室内温度影响较大;当覆盖率分别为0。
A multiobjective optimization for a two-stage axial-flow compressor design was performed for maximization of the overall adiabatic efficiency and the total pressure ratio.
针对一台两级轴流压气机,选定优化设计的目标是最大的总压比和最高的总绝热效率。
The hot temperature difference and adiabatic efficiency increased by increasing cold air fraction,but cold temperature difference decreased.
冷流比增加,涡流板制热效应和绝热效率增加,而制冷效应下降.
that is, to increase the overall thermal efficiency of such units
即提高这种机组总的热效率
dry adiabatic lapse rate
干绝热〔温度〕递减率;干绝热〔温度〕直减率
Theoretical Analysis of the Adiabatic Shear Band Width and Strain Rate Effect of Ti-6Al-4V
Ti-6Al-4V绝热剪切带的厚度及应变率效应研究
Efficent Duplicate Hot Standby System Based on Fieldbus
一种基于现场总线的高效率双机热备实现方案
The highest adiabatic efficiency is increased by7.4% and the stability operation margin also has a notable increase.
最高绝热效率提高了7.4个百分点,稳定工作裕度也有了显著的增加。
The highest adiabatic efficiency is increased by 7 4% and the stability operation margin also has a notable increase.
最高绝热效率提高了7.4 个百分点,稳定工作裕度也有了显著的增加
insulation test for refrigerated cargo chamber
冷藏货舱绝热效能试验
Thermal conductivity measuring equipment of adiabatic material at low temperature
非金属绝热材料低温热导率测试装置
thermal balance and thermal efficiency of furnaces inmetallurgical industry
冶金炉热平衡和热效率
Analysis on thermal bridge effects of vacuum insulation panel
真空绝热板(VIP)热桥效应分析
The result proves that the adiabatic saturation temperature at the desulphuration tower outlet has the most evident influence on the desulphuration efficiency of the system, and the ratio of calcium to sulfur comes next.
结果表明:对系统脱硫效率影响最显著的参数是脱硫塔出口趋近绝热饱和温度,其次为钙硫比。
Bare copper flat wire technology is adopted for wire package,with H class insulant as bedding to realize functions like : quick heat dissipation,high efficiency and long working life.
线包采用丝包铜扁线技术工艺,用H级绝缘材料垫层,散热快、效率高、寿命长。
testing method for coefficient of linear expansion and shrinkage of insulating fire bricks during heating
绝热耐火砖线膨胀收缩率试验方法
testing method for reheat shrinkage of insulating fire bricks
绝热耐火砖重烧收缩率试验方法
testing method for specific gravity and true porosity of insulating fire bricks
绝热耐火砖比重和真气孔率测定方法
ADIABATIC TEMPERATURE LAPSE RATE IN CLOUD AND ITS RELATIONSHIP WITH MICROSTRUCTURE
云中绝热温度递减率同微结构的关系
CopyRight © 2020-2024 优校网[www.youxiaow.com]版权所有 All Rights Reserved. ICP备案号:浙ICP备2024058711号