The capacitive coupling between busbars has an effect on ferroresonance occurring on neutral-grounded systems.
利用EMTP软件模拟了相间电容对中性点接地系统空母线上铁磁谐振的影响。
Development and prospect of the single-phase grounding fault detection in unearthed or compensated neutral networks;
中性点非直接接地系统故障选线原理的发展与展望
Compared with neutral ungrounded power system, ferroresonance overvoltage occurred in neutral grounded power system has more new features, and the research about it is much .
相对于中性点非直接接地系统而言,发生在中性点直接接地系统中的铁磁谐振过电压有着许多新的特点,而且对它的研究相对较少。
Non-ground neutral system and arc-suppression-coil-ground neutral system are called non-direct ground neutral system that is widely used in power distribution system.
中性点不接地系统和中性点经消弧线圈接地系统统称为中性点不直接接地系统,广泛应用于铁路配电系统中。
Non-ground neutral system and arc-suppression-coil-ground neutral system are called non-direct ground neutral system.
中性点不接地系统和中性点经消弧线圈接地系统统称为中性点不直接接地系统,广泛应用于铁路配电系统中。
Preventive measure of ferro-resonance for isolated neutral system;
防止中性点不接地系统铁磁谐振的措施
A resonance eliminating method for isolated neutral system;
中性点不接地系统的一种消谐方法
The abnormal voltage of 35kV isolated neutral system is analyzed after the phase I(phase II) of its busbar TV high-voltage fuse is fused,and then the causes are found out,which not only can help the operator determine the similar faults accurately in time,but can help to prevent the undetected faults damaging the potential transformer.
通过对一起35 kV中性点不接地系统母线电压互感器高压熔断器一相(二相)熔断后电压异常的实例现象分析,找出其原因,有利于发生类似故障时运行人员能够准确及时的判断处理,防止长期未发现故障使电压互感器损坏。
Ferromagnetic Resonance Over-voltage in Neutral-point Indirect Earthing System
中性点非直接接地系统铁磁谐振的产生及措施
The Simulation in Research on Ferroresonance in Grounded Neutral Point;
中性点直接接地系统铁磁谐振的数学仿真
The discussion of line-to-neutral voltage regularity and judgment of grounded phase when isolated neutral system is nonmetal grounded
中性点不接地系统单相接地时接地相的判断
Studies on New Methods of Faulted Line Identification in Non-effectively Grounded System;
中性点非有效接地系统单相接地故障选线新方法研究
Research on Traveling Wave-Based Fault Location Schemes for Single-Phase-to-Earth Faults in Neutral Ineffectively Grounded Systems;
中性点非有效接地系统单相接地行波定位方法的研究
Research on the Detection of Faulty Line in Non-Direct Grounded Neutral System;
中性点非有效接地系统单相接地故障选线的研究
Research on Line Detection and Fault Location for Single-Phase-to-Earth Fault in Neutral Ineffectively Grounded Systems;
中性点非有效接地系统单相接地的选线与定位方法研究
Research on Fault Location Methods for Single-Phase-To-Earth Faults in Neutral Ineffectively Grounded Systems
中性点非有效接地系统单相接地故障定位方法的研究
Analysis of transient characteristics of fault generated traveling waves in non-effective grounding system;
中性点非有效接地系统故障行波暂态特征分析
The Study on Suppression of PT Ferroresonance in Neutral-grounded System;
中性点直接接地系统PT铁磁谐振抑制措施的研究
Discuss on Earthing Protection Scheme in Neutral Grounded with Low-resistance Distributed System
中性点经小电阻接地系统接地保护方案探讨
Introduction to neutral grounding and resistance grounding in distribution system
配电系统中性点接地方式及电阻接地方式
resistance-grounded neutral system
中心点电阻接地系统
Fault Location of Transmission Line in Non-Effective Grounded Neutral System Based on Monte-Carlo Method
基于Monte Carlo方法的中性点非有效接地系统输电线路故障测距
neutral grounding of power system
电力系统中性点接地方式
AC three phase four wire system with neutral earthed
中性点接地的交流三相四线系统
Influence of Vertical Earth on Electricity Performance of Grounding System
垂直接地极对接地系统电气性能的影响
A new scheme of microprocessor based earthing protection in neutral earthing via arc extinguishing coil system
中性点经消弧线圈接地系统微机接地保护新方案
CopyRight © 2020-2024 优校网[www.youxiaow.com]版权所有 All Rights Reserved. ICP备案号:浙ICP备2024058711号