Getting Going from precise production of heat treatment industry and high quality and efficiency whole strategy, the miscarriage of justice that may appear in the measuring process of efficient heating region of heat treatment furnace and the problem of vacuum furnace measured by non-removable thermocouple assay was discussed.
从热处理行业的精确生产及优质高效的整体战略出发,探讨了热处理炉有效加热区测量过程中,可能出现的误判及真空炉用不可拆卸热电偶检定过程中存在的问题,详细论述了当前热处理炉用测温系统采用分立元件检定法的弊端及对策,倡导采用现场在线整体校准法,以求进一步提高测温精度。
This paper depicted the mostiy technic content of GB/T9452-2003(Testing method for work zone of heat treatment furnace),and analysed the differential and actualize advertent proceeding of the standard and old standard.
本文给出了热处理炉有效加热区测定方法GB/T9452-2003中的一些主要技术内容,并分析了该标准与原GB/T9452-1988的异同点及实施注意事项等。
By utilizing a multipinhole array coupled to a soft X-ray streak camera, the plasma evolution in laser heated area(primary plasmas) and X-ray heated area(secondary plasmas) was observed.
首次利用多针孔阵列成像技术结合软X光扫描相机观察激光加热区和X光加热区等离子体的运动,获得了初级和次级等离子体膨胀速度等结果。